Plumbing, i need to replace water pipes?


Question:can i use compression fittings instead of soldering and what size copper do i use?

Answers:
Do not listen to those saying "use 1/2 inch copper". A gross generalization. Yes, 1/2" used at point of termination (directly under a sink, toilet, etc. The very smallest pipe to use as main lines is 3/4". I have used 1" on jobs exceeding 100' of main line. Consider this; 1" pipe not that much more expensive than 1/2".but 1" is 4 times (yes, four times) more volume than 1/2". Do the math, you'll see. (area of a circle, e.g.) Piping in industrial applications 1 1/2", even 2". Bigger the line, better the water pressure.
Don't be afraid of soldering. Read a book. Practice a little. It's not as hard as it looks. Also, some hardware stores (Home Depot is one) sell "presoldered" fittings. In the long term, you'll be sorry if using compression or plastic.
A critical matter: copper cannot be connected to other metals (other than brass) including mounting brackets (use plastic or copper coated clamps) If you must connect to galvanized or black steel don't just use a dialectric union, use a brass nipple on each side of dialectric union (at least 6" each) as a buffer. Otherwise your copper will quickly corrode.
Keep future repair and alteration in mind too, allow for shut off valves and make main lines easily accessible, install tees with ball valves in areas you anticipate additions. Consider (if in your budget) designing path of pipe in a "loop"; in other words, where pipe enters house, travels toward sinks, showers, appliances, route the pipe so that it connects back near entry.not dead end everywhere. You will experience a huge difference in consistent water pressure. remember, new construction plumbing is usually performed by the lowest bidder; not in the best interest of the resident/user.


1/2 copper is what you use. I don't see any reason you couldn't use compression fittings if you are not going to get it inspected. I used high pressure PVC on a rental unit I have and ten years ago and had no problems.
for your main water lines in your home you should use 1/2" copper pipe.
This is a solder connection because it often runs through walls, or floors where a poor connection could result in a leak and be very difficult to get to, and cause problems or inconvinience until it is repaired. A compression fitting is generally used at a device and not along main runs because it is a good connection but not as good as a soldered connection. Any time you have joining in a temporary fashion, the potential to leak is greater. A temporary connection is any type of connection that can be disassembled. Solder cannot be just disassembled it has to literally be unsoldered or cut to undo the connection. I would not use a method less secure than a soldered connection for my main runs.
You could use CPVC, requires just glueing and watching for expansion, also useable for water to 180 °F, for the main lines use 3/4" and closer to the faucets use ½"
First: You have to have a plan. When I did mine over I sat down and made a "road map" of my entire water system. It was a road map of the pipes and where I would put what.

I put in 1" water pipe for the main line. From the well, which I had just had cleaned and a new pump with a 1" outlet. I thought why put a 1/2" or a 3/4" line when it's a 1" I would be defeating the purpose of the well. So I put in a 1" line to all the main places where I'd be plumbing.
For the ones I used all the time, the clothes washer, the water heater, I put in 3/4" lines. Where it went to a sink IE: bath sink I put in 1/2" lines (less water use) where it went to an outside bib, I put in 3/4" lines and a 3/4" hose on the outside.

I used copper fittings and did all the work myself, new pipe. I had the pump guy set the pressure at 65 pounds with a bladder tank. I can turn on all the water in the house and still take a shower with no perceptible loss of water pressure, it's so nice.
This is the only way to go. I wouldn't think of pvc or pressure fittings, copper is made "forever" if done right.
If it the main water line coming from the meter it's 3/4 and then it reduces to 1/2. That's the code in Ohio. Lowes/Home Depot have this new product out (I think it's)called shark grip fittings. They are compression fittings but instead of using a pipe wrench to tighten them they slip on. You just cut the pipe like regular and then Push them on. We just used them on a rental we own when we put a new bathroom in. They are awesome so easy! If you every have to take them off there this little orange tool that pops them off. I've been doing maintenance for 10 years. trust me you'll love them.

More Related Questions & Answers...
  • Can anyone recommend a good Master Electrician in the Phoenix, AZ metro area?
  • Central AC problems--any ideas?
  • Any Air Conditioning people out there?
  • What tool can I use to adjust my Hunter ingournd sprinklers?
  • Can I get out of a lease if the landlord does not fix major problems, what can i do?
  • Need to find a kitchen sink 34" wide; standard is 33"; want new. Any ideas?
  • Wiring ceiling fan to power and control wires from ceiling??
  • Changing screens with aluminum spline?
  • What are the chances of bubbling or chipping the plaster in a swimming pool if it is drained?
  • What is the best way to dispute a bill for a service call when nothing was serviced?
  • If a radiator have a cover on it is it okay to put things on it?
  • This article contents is create by this website user, FindHomeAnswers.com doesn't promise its accuracy.
    Copyright 2007-2008 FindHomeAnswers.com     Contact us    Terms of Use

    Home and Garden